Description
Overview
The ARI-SAFE Fig. 25.901 (from manufacturer datasheet 900005, Edition 04/20) is a full lift safety valve D/G, direct loaded with spring, flanged, closed lifting device, closed bonnet. The Fig. 25.901 body is EN-JS1049 spheroidal graphite iron, PN40/16, nominal diameter DN20/32 – DN250/350 (inlet/outlet), temperature range -10 °C to +350 °C.
The same datasheet family covers Fig. 12.901 (PN16, EN-JL1040, up to 300 °C), Fig. 34.901/35.901 (PN25/PN40, 1.0619+N cast steel, up to 450 °C), Fig. 55.901 (1.4408 stainless, -60 °C to +400 °C), plus variants Fig. 902 (open lifting device/open bonnet), Fig. 911 (gastight cap), Fig. 912 (open lifting device/closed bonnet), heating-technology versions (Fig. 903/904) and ARI-SAFE-P/TC/TCP/TCS derivatives. The data on this page refers to Fig. 25.901.
Features
- Direct loaded with spring
- Full lift safety valve D/G (standard safety valve F available as Fig. 901/911)
- Wear resistant seat/disc
- Precision disc alignment and guide
- Possible with soft seal disc, EPDM bellows or stainless steel bellows (metal bellows optional DN15/25–100/150)
- Variants: closed lifting device/closed bonnet (.901), open/open (.902), gastight cap (.911), open lifting device/closed bonnet (.912)
Approvals
- Type-test approved acc. to DIN EN ISO 4126-1 / AD2000-A2 / TRD 421
- Full lift safety valve: TÜV · SV · ..-663 · D/G, Fig. 901/902/911/912
- Standard safety valve: TÜV · SV · ..-663 · F, Fig. 901/911
- VdTÜV-leaflet 100; material selection observe TRB 801 No. 45
Technical data
- Type: full lift safety valve, spring loaded, direct loaded, flanged
- Figure: Fig. 25.901
- Nominal pressure: PN40/16 (inlet/outlet)
- Nominal diameter: DN20/32 – DN250/350
- Body material: EN-JS1049 / EN-GJS-400-18U-LT
- Temperature range: -10 °C to +350 °C
- Flanges: acc. to DIN EN 1092-2
- Back pressure: superimposed — none allowed (standard); built-up — max. 10 % of set pressure (higher on request)
Spring ranges
Spring ranges (standard design, full lift D/G) start at 0.2 bar and span to 40 bar depending on DN1/DN2 and spring; e.g. DN25/40: 0.2–0.5 bar up to 25.9–40 bar. The full spring-range table per DN is on datasheet page 3. Sizing is by capacity tables for steam, air and water (datasheet p5–7), calculations acc. to EN ISO 4126-1, TRD 421 and AD2000-A2.
Dimensions
Datasheet p4, main dimensions (per DN1/DN2):
| DN1/DN2 | 20/32 | 25/40 | 32/50 | 40/65 | 50/80 | 65/100 | 80/125 | 100/150 | 125/200 | 150/250 | 200/300 | 250/350 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| d0 (mm) | 18 | 22,5 | 29 | 36 | 45 | 58,5 | 72 | 90 | 106 | 125 | 165 | 200 |
| A0 (mm²) | 254 | 398 | 661 | 1018 | 1590 | 2688 | 4072 | 6362 | 8825 | 12272 | 21382 | 31416 |
| l (mm) | 85 | 100 | 110 | 115 | 120 | 140 | 160 | 180 | 200 | 225 | 300 | 325 |
| l1 (mm) | 95 | 105 | 115 | 140 | 150 | 170 | 195 | 220 | 250 | 285 | 305 | 340 |
| H (mm) | 270 | 280 | 330 | 390 | 435 | 545 | 610 | 690 | 845 | 890 | 1105 | 1175 |
| Weight standard (kg) | 8,5 | 10 | 14 | 20 | 28 | 40 | 53 | 80 | 125 | 165 | 280 | 430 |
Ordering information
Please indicate when ordering: ARI-SAFE safety valve, figure no. (e.g. 25.901), DN1/DN2, PN, material and set pressure in bar.
For sizing and a quotation, please send: medium, mass flow (kg/h), temperature, set pressure (barg) and back pressure (barg) — for liquids additionally density and viscosity.